{"id":7259,"date":"2026-04-11T16:11:48","date_gmt":"2026-04-11T08:11:48","guid":{"rendered":"https:\/\/www.ahkfjx.com\/?p=7259"},"modified":"2026-04-15T17:26:39","modified_gmt":"2026-04-15T09:26:39","slug":"why-water-cooled-industrial-chillers-are-more-energy-efficient","status":"publish","type":"post","link":"https:\/\/www.ahkfjx.com\/de\/why-water-cooled-industrial-chillers-are-more-energy-efficient\/","title":{"rendered":"Warum wassergek\u00fchlte Industriek\u00e4ltemaschinen energieeffizienter sind"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"7259\" class=\"elementor elementor-7259\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-04102ab e-flex e-con-boxed e-con e-parent\" data-id=\"04102ab\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fe9a10f elementor-widget elementor-widget-text-editor\" data-id=\"fe9a10f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Es gibt einen Grund, warum gro\u00dfe Anlagen fast immer wassergek\u00fchlte K\u00e4ltemaschinen verwenden. Es geht nicht um die Komplexit\u00e4t oder die ersten Kosten, sondern um die Effizienz. Eine gut konzipierte wassergek\u00fchlte Industriek\u00e4ltemaschine kann f\u00fcr die gleiche Aufgabe deutlich weniger Strom verbrauchen als eine luftgek\u00fchlte Einheit. Im Laufe der Betriebsjahre summiert sich dieser Unterschied zu echtem Geld.<\/p><p>Wenn man sich die Energierechnungen von Anlagen ansieht, die von Luft- auf Wasserk\u00fchlung umgestellt wurden, sind die Einsparungen kaum zu \u00fcbersehen. Aber warum genau sind sie effizienter? Die Antwort hat damit zu tun, wie die W\u00e4rme abgeleitet wird und wie die Kompressoren arbeiten.<\/p><p>Dies ist ein Blick auf die physikalischen und technischen Gr\u00fcnde, warum ein <a href=\"https:\/\/www.ahkfjx.com\/de\/product\/water-cooled-chiller\/\"><strong>wassergek\u00fchlte industrielle K\u00e4ltemaschine<\/strong><\/a> gewinnt durch Effizienz.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ccb07a9 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"ccb07a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/02\/Water-cooled-chiller18-1024x768.jpg\" class=\"attachment-large size-large wp-image-3648\" alt=\"Wassergek\u00fchlte K\u00e4ltemaschine\" srcset=\"https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/02\/Water-cooled-chiller18-1024x768.jpg 1024w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/02\/Water-cooled-chiller18-300x225.jpg 300w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/02\/Water-cooled-chiller18-768x576.jpg 768w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/02\/Water-cooled-chiller18-1536x1152.jpg 1536w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/02\/Water-cooled-chiller18.jpg 2016w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ddef9b elementor-widget elementor-widget-heading\" data-id=\"1ddef9b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Die physikalischen Grundlagen der Effizienz von wassergek\u00fchlten Industriek\u00fchlern<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7e8e5cb elementor-widget elementor-widget-text-editor\" data-id=\"7e8e5cb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Effizienz einer K\u00e4ltemaschine h\u00e4ngt von einer Sache ab: wie stark der Kompressor arbeiten muss, um die W\u00e4rme vom Verdampfer zum Verfl\u00fcssiger zu transportieren. Je niedriger die Verfl\u00fcssigertemperatur, desto weniger Arbeit hat der Kompressor.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-246dc07 elementor-widget elementor-widget-heading\" data-id=\"246dc07\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Luft vs. Wasser als W\u00e4rme\u00fcbertragungsmedium<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-59b0f76 elementor-widget elementor-widget-text-editor\" data-id=\"59b0f76\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Luft ist im Vergleich zu Wasser eine schlechte W\u00e4rme\u00fcbertragungsfl\u00fcssigkeit. Sie hat eine geringe W\u00e4rmeleitf\u00e4higkeit und eine niedrige spezifische W\u00e4rme. Wasser hingegen kann W\u00e4rme hervorragend ableiten. Aus diesem Grund verwenden Autok\u00fchler Wasser (oder K\u00fchlmittel) und nicht nur Luft.<\/p><p>Eine wassergek\u00fchlte Industriek\u00e4ltemaschine macht sich dies zunutze. Der Verfl\u00fcssiger verwendet Wasser, das mit einer Temperatur von etwa 85\u00b0F aus einem K\u00fchlturm gepumpt wird, um die W\u00e4rme des K\u00e4ltemittels zu absorbieren. Eine luftgek\u00fchlte K\u00e4ltemaschine verwendet Umgebungsluft, die an einem hei\u00dfen Sommertag 95\u00b0F oder mehr haben kann, und Luft absorbiert W\u00e4rme nicht ann\u00e4hernd so effizient.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b9497cd elementor-widget elementor-widget-heading\" data-id=\"b9497cd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Feuchtkugel- vs. Trockenkugeltemperatur<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-92610aa elementor-widget elementor-widget-text-editor\" data-id=\"92610aa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Dies ist der Schl\u00fcsselbegriff. Eine <a href=\"https:\/\/www.ahkfjx.com\/de\/product\/air-cooled-chiller\/\"><strong>luftgek\u00fchlte K\u00e4ltemaschine<\/strong><\/a> wird durch die Trockenkugeltemperatur - die tats\u00e4chliche Lufttemperatur - begrenzt. An einem Tag mit 100\u00b0F hat die Luft 100\u00b0F. Die Verfl\u00fcssigungstemperatur der K\u00e4ltemaschine liegt bei mindestens 100\u00b0F, in der Regel h\u00f6her.<\/p><p>Eine wassergek\u00fchlte K\u00e4ltemaschine wird jedoch durch die Feuchtkugeltemperatur begrenzt - die Temperatur, die Luft h\u00e4tte, wenn sie mit Feuchtigkeit ges\u00e4ttigt w\u00e4re. K\u00fchlt\u00fcrme k\u00fchlen Wasser durch Verdunstung, und die Verdunstung kann die Wassertemperatur nahe an die Feuchtkugeltemperatur heranbringen. An einem Tag mit einer Trockenkugeltemperatur von 100\u00b0F kann die Feuchtkugeltemperatur nur 75\u00b0F betragen. Das ist eine um 25\u00b0F niedrigere Kondensationstemperatur.<\/p><p>Eine niedrigere Verfl\u00fcssigungstemperatur bedeutet ein niedrigeres Druckverh\u00e4ltnis des Verdichters. Ein niedrigeres Druckverh\u00e4ltnis bedeutet weniger Arbeit. Weniger Arbeit bedeutet weniger Strom.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5598050 elementor-widget elementor-widget-heading\" data-id=\"5598050\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wie sich die Verfl\u00fcssigungstemperatur auf eine wassergek\u00fchlte Industriek\u00e4ltemaschine auswirkt<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0abbe8a elementor-widget elementor-widget-text-editor\" data-id=\"0abbe8a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Lassen Sie uns dies mit ein paar Zahlen belegen. Eine typische wassergek\u00fchlte Industriek\u00e4ltemaschine k\u00f6nnte an einem warmen Tag mit einer Verfl\u00fcssigungstemperatur von 95\u00b0F laufen. Eine luftgek\u00fchlte K\u00e4ltemaschine k\u00f6nnte am selben Tag mit einer Verfl\u00fcssigungstemperatur von 115\u00b0F laufen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fb03e58 elementor-widget elementor-widget-tablepress-table\" data-id=\"fb03e58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"tablepress-table.default\">\n\t\t\t\t\t\n<table id=\"tablepress-54\" class=\"tablepress tablepress-id-54\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Parameter<\/th><th class=\"column-2\">Wassergek\u00fchlt<\/th><th class=\"column-3\">Luftgek\u00fchlt<\/th><th class=\"column-4\">Unterschied<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Verfl\u00fcssigungstemperatur<\/td><td class=\"column-2\">95\u00b0F (35\u00b0C)<\/td><td class=\"column-3\">115\u00b0F (46\u00b0C)<\/td><td class=\"column-4\">20\u00b0F h\u00f6her<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Verfl\u00fcssigungsdruck (R134a)<\/td><td class=\"column-2\">~120 psig<\/td><td class=\"column-3\">~170 psig<\/td><td class=\"column-4\">50 psig h\u00f6her<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Leistung des Verdichters (relativ)<\/td><td class=\"column-2\">1.0<\/td><td class=\"column-3\">1.25-1.35<\/td><td class=\"column-4\">25-35% mehr Energie<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7350e54 elementor-widget elementor-widget-text-editor\" data-id=\"7350e54\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Dieser Unterschied von 20\u00b0F in der Verfl\u00fcssigungstemperatur schl\u00e4gt sich direkt in einer h\u00f6heren Verdichterleistung nieder. Die luftgek\u00fchlte K\u00e4ltemaschine arbeitet h\u00e4rter, um das K\u00e4ltemittel gegen den h\u00f6heren Druck zu dr\u00fccken.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1241ee elementor-widget elementor-widget-heading\" data-id=\"c1241ee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\"> Die Auswirkungen des hei\u00dfen Wetters<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-84e612a elementor-widget elementor-widget-text-editor\" data-id=\"84e612a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Effizienzl\u00fccke wird mit steigender Au\u00dfentemperatur gr\u00f6\u00dfer. An einem milden Tag mit 75\u00b0F k\u00f6nnte eine luftgek\u00fchlte K\u00e4ltemaschine einigerma\u00dfen effizient sein. An einem Tag mit 105\u00b0F hat sie Schwierigkeiten. Der Verfl\u00fcssigungsdruck steigt an. Der Verdichter arbeitet h\u00e4rter. Die K\u00e4ltemaschine kann sogar einen Leistungsabfall aufweisen, d. h. weniger K\u00fchlleistung bei h\u00f6herem Stromverbrauch.<\/p><p>Bei einer wassergek\u00fchlten Industriek\u00e4ltemaschine hingegen sinkt der Wirkungsgrad an hei\u00dfen Tagen nur geringf\u00fcgig. Die Feuchtkugeltemperatur steigt viel weniger stark an als die Trockenkugeltemperatur. An einem Tag mit einer Trockenkugeltemperatur von 105\u00b0F k\u00f6nnte die Feuchtkugeltemperatur 78\u00b0F betragen. Der K\u00fchlturm liefert immer noch Wasser mit einer Temperatur von 85\u00b0F. Die K\u00e4ltemaschine merkt die Hitzewelle kaum.<\/p><p>Aus Beobachtungsgr\u00fcnden entscheiden sich Rechenzentren und Krankenh\u00e4user - Einrichtungen, die auch bei Hitzewellen eine zuverl\u00e4ssige K\u00fchlung ben\u00f6tigen - fast immer f\u00fcr eine Wasserk\u00fchlung.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4f6c00f elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"4f6c00f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/02\/Air-cooled-chiller4-1024x768.jpg\" class=\"attachment-large size-large wp-image-3580\" alt=\"Luftgek\u00fchlte K\u00e4ltemaschine\" srcset=\"https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/02\/Air-cooled-chiller4-1024x768.jpg 1024w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/02\/Air-cooled-chiller4-300x225.jpg 300w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/02\/Air-cooled-chiller4-768x576.jpg 768w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/02\/Air-cooled-chiller4-1536x1152.jpg 1536w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/02\/Air-cooled-chiller4.jpg 2016w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-55d6a4e elementor-widget elementor-widget-heading\" data-id=\"55d6a4e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"> Effizienz im Teillastbereich und der Vorteil der Wasserk\u00fchlung<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bdaa97f elementor-widget elementor-widget-text-editor\" data-id=\"bdaa97f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Kaltwassers\u00e4tze laufen selten unter Volllast. Die meiste Zeit laufen sie mit einer Kapazit\u00e4t von 40-70%. Wie eine K\u00e4ltemaschine bei Teillast arbeitet, ist wichtiger als ihre Effizienz bei Volllast.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-32826d8 elementor-widget elementor-widget-heading\" data-id=\"32826d8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Wie wassergek\u00fchlte K\u00e4ltemaschinen mit Teillast umgehen<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3eebeba elementor-widget elementor-widget-text-editor\" data-id=\"3eebeba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Eine wassergek\u00fchlte Industriek\u00e4ltemaschine mit einem drehzahlgeregelten Antrieb des Verdichters und drehzahlgeregelten Turmventilatoren kann einen hervorragenden Wirkungsgrad bis zu einer Last von 20-30% beibehalten. Die Verfl\u00fcssigerwassertemperatur kann bei niedriger Last nach oben korrigiert werden, um Energie f\u00fcr die Turmventilatoren zu sparen, aber die K\u00e4ltemaschine arbeitet immer noch mit niedrigem Verfl\u00fcssigungsdruck.<\/p><p>Luftgek\u00fchlte K\u00e4ltemaschinen haben bei Teillast mehr M\u00fche. Die Verfl\u00fcssigerl\u00fcfter schalten sich ein und aus oder laufen mit festen Drehzahlen. Es kann sein, dass die K\u00e4ltemaschine die Ventilatoren st\u00e4rker als n\u00f6tig laufen lassen muss, nur um den minimalen Verfl\u00fcssigungsdruck aufrechtzuerhalten, insbesondere bei k\u00fchlem Wetter.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6838db4 elementor-widget elementor-widget-heading\" data-id=\"6838db4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Integrierter Teillastwert (IPLV)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b407331 elementor-widget elementor-widget-text-editor\" data-id=\"b407331\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Industrie misst den Teillastwirkungsgrad mit IPLV (Integrated Part Load Value). Eine gute wassergek\u00fchlte Industriek\u00e4ltemaschine k\u00f6nnte einen IPLV von 0,35-0,45 kW\/Tonne haben. Eine luftgek\u00fchlte K\u00e4ltemaschine \u00e4hnlicher Gr\u00f6\u00dfe liegt bei 0,70-0,85 kW\/Tonne. Die wassergek\u00fchlte Einheit verbraucht unter typischen Betriebsbedingungen etwa die H\u00e4lfte des Stroms.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30aa95f elementor-widget elementor-widget-heading\" data-id=\"30aa95f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Energieeinsparungen in der realen Welt<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d5842ec elementor-widget elementor-widget-text-editor\" data-id=\"d5842ec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Lassen Sie uns ein Beispiel durchspielen. Eine 300-Tonnen-K\u00e4ltemaschine l\u00e4uft 4.000 Stunden pro Jahr (typisch f\u00fcr eine Produktionsanlage oder ein Rechenzentrum). Elektrizit\u00e4t zu $0,12 pro kWh.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4cc1771 elementor-widget elementor-widget-tablepress-table\" data-id=\"4cc1771\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"tablepress-table.default\">\n\t\t\t\t\t\n<table id=\"tablepress-55\" class=\"tablepress tablepress-id-55\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">K\u00fchler Typ<\/th><th class=\"column-2\">Volllast kW\/Tonne<\/th><th class=\"column-3\">IPLV kW\/Tonne<\/th><th class=\"column-4\">J\u00e4hrliche kWh<\/th><th class=\"column-5\">J\u00e4hrliche Kosten<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Wassergek\u00fchlt<\/td><td class=\"column-2\">0.55<\/td><td class=\"column-3\">0.45<\/td><td class=\"column-4\">540,000<\/td><td class=\"column-5\">$64,800<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Luftgek\u00fchlt<\/td><td class=\"column-2\">0.85<\/td><td class=\"column-3\">0.75<\/td><td class=\"column-4\">900,000<\/td><td class=\"column-5\">$108,000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4c8a2b3 elementor-widget elementor-widget-text-editor\" data-id=\"4c8a2b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die wassergek\u00fchlte K\u00e4ltemaschine spart $43.200 pro Jahr an Stromkosten. Bei einer Lebensdauer von 20 Jahren macht das $864.000 an vermiedenen Energiekosten aus. Damit l\u00e4sst sich eine Menge an K\u00fchlturmwartung bezahlen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8d9b11d elementor-widget elementor-widget-heading\" data-id=\"8d9b11d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\"> Die erste Kostenabw\u00e4gung<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-859bd58 elementor-widget elementor-widget-text-editor\" data-id=\"859bd58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wassergek\u00fchlte K\u00e4ltemaschinen sind in der Anschaffung teurer. Die K\u00e4ltemaschine selbst ist teurer. Hinzu kommen ein K\u00fchlturm, Kondensatorwasserpumpen, Rohrleitungen und Wasseraufbereitung. Die Installationskosten f\u00fcr ein wassergek\u00fchltes System k\u00f6nnen 30-50% h\u00f6her sein als f\u00fcr ein luftgek\u00fchltes System.<\/p><p>Aber die Amortisationszeit ist oft kurz. Wenn im obigen Beispiel das wassergek\u00fchlte System zun\u00e4chst $150.000 mehr kostet, betr\u00e4gt die Amortisationszeit allein durch die Energieeinsparungen etwa 3,5 Jahre. Danach geht es nur noch um Einsparungen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0737fcf elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"0737fcf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/02\/Air-cooled-chiller2-1024x768.jpg\" class=\"attachment-large size-large wp-image-3578\" alt=\"Luftgek\u00fchlte K\u00e4ltemaschine\" srcset=\"https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/02\/Air-cooled-chiller2-1024x768.jpg 1024w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/02\/Air-cooled-chiller2-300x225.jpg 300w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/02\/Air-cooled-chiller2-768x576.jpg 768w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/02\/Air-cooled-chiller2-1536x1152.jpg 1536w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/02\/Air-cooled-chiller2.jpg 2016w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-47cc8f6 elementor-widget elementor-widget-heading\" data-id=\"47cc8f6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Andere Faktoren, die die Effizienz beeinflussen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ce1e3bc elementor-widget elementor-widget-text-editor\" data-id=\"ce1e3bc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Neben der grundlegenden Thermodynamik tragen noch einige andere Faktoren zum Effizienzvorteil einer wassergek\u00fchlten Industriek\u00e4lteanlage bei.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-144d339 elementor-widget elementor-widget-heading\" data-id=\"144d339\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Kompressortyp<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d5fa1cd elementor-widget elementor-widget-text-editor\" data-id=\"d5fa1cd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In wassergek\u00fchlten K\u00e4ltemaschinen kommen h\u00e4ufig Zentrifugal- oder Schraubenverdichter zum Einsatz, die bei gro\u00dfen Leistungen von Natur aus effizienter sind als die in luftgek\u00fchlten Ger\u00e4ten \u00fcblichen Scrollverdichter. Zentrifugalkompressoren haben keine reibenden Teile und k\u00f6nnen sehr niedrige kW\/Tonne erreichen, insbesondere bei gro\u00dfen Kapazit\u00e4ten.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f16690f elementor-widget elementor-widget-heading\" data-id=\"f16690f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Konstruktion von W\u00e4rmetauschern<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6cc634f elementor-widget elementor-widget-text-editor\" data-id=\"6cc634f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wassergek\u00fchlte K\u00e4ltemaschinen verwenden Rohrb\u00fcndelw\u00e4rmetauscher. Diese haben hervorragende W\u00e4rme\u00fcbertragungskoeffizienten - viel besser als die Rippenrohrschlangen in luftgek\u00fchlten Ger\u00e4ten. Das bedeutet, dass f\u00fcr die W\u00e4rme\u00fcbertragung geringere Temperaturunterschiede erforderlich sind, was die Verdichterarbeit weiter reduziert.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2c4cfc8 elementor-widget elementor-widget-heading\" data-id=\"2c4cfc8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Potential f\u00fcr freie K\u00fchlung<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4062cef elementor-widget elementor-widget-text-editor\" data-id=\"4062cef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bei k\u00fchler Witterung k\u00f6nnen einige wassergek\u00fchlte Systeme den K\u00fchlturm direkt f\u00fcr die Bereitstellung von Kaltwasser nutzen, ohne dass der Kompressor der K\u00e4ltemaschine l\u00e4uft. Dies wird als freie K\u00fchlung bezeichnet. Bei einer Bypass-Anordnung wird das Wasser des K\u00fchlturms durch einen W\u00e4rmetauscher geleitet (oder direkt an die Verbraucher), wenn die Feuchtkugeltemperatur niedrig genug ist. Luftgek\u00fchlte K\u00e4ltemaschinen k\u00f6nnen dies nicht - sie m\u00fcssen die Kompressoren immer dann laufen lassen, wenn K\u00fchlung ben\u00f6tigt wird.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-352f52b elementor-widget elementor-widget-heading\" data-id=\"352f52b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"> Ist wassergek\u00fchlt immer effizienter?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-800b4b1 elementor-widget elementor-widget-text-editor\" data-id=\"800b4b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Fast immer, aber es gibt auch Ausnahmen.<\/p><p>Eine wassergek\u00fchlte Industriek\u00e4ltemaschine ben\u00f6tigt Pumpen, um das Kondensationswasser zu f\u00f6rdern. Diese Pumpen verbrauchen Strom.<\/p><p>Ein K\u00fchlturm verwendet Ventilatoren. F\u00fcr die Wasseraufbereitung werden Chemikalien und manchmal auch Strom ben\u00f6tigt. Diese Zusatzlasten verringern den Netto-Wirkungsgradvorteil geringf\u00fcgig.<\/p><p>In sehr kalten Klimazonen kann eine luftgek\u00fchlte K\u00e4ltemaschine die niedrigen Umgebungstemperaturen ausnutzen, um einen guten Wirkungsgrad zu erzielen. An einem Tag mit 40\u00b0F kann eine luftgek\u00fchlte K\u00e4ltemaschine fast genauso gut arbeiten wie ein wassergek\u00fchltes Ger\u00e4t.<\/p><p>Aber \u00fcber ein ganzes Jahr hinweg gewinnt in den meisten Klimazonen die Wasserk\u00fchlung. Am gr\u00f6\u00dften ist der Unterschied in hei\u00dfen, feuchten Klimazonen, in denen die Leistung von luftgek\u00fchlten Ger\u00e4ten am meisten leidet.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1633b46 elementor-widget elementor-widget-heading\" data-id=\"1633b46\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Das Endergebnis f\u00fcr Ihre Einrichtung<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ae64bbb elementor-widget elementor-widget-text-editor\" data-id=\"ae64bbb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bei der Wahl einer K\u00e4ltemaschine geht es um mehr als nur Effizienz. Wasserverf\u00fcgbarkeit, Wartungsm\u00f6glichkeiten, Platzbedarf, Ger\u00e4uschentwicklung und Anschaffungskosten spielen eine Rolle.<\/p><p>Wenn jedoch Energieeffizienz im Vordergrund steht - und das ist bei vielen Anlagen der Fall - ist eine wassergek\u00fchlte Industriek\u00e4ltemaschine die klare Wahl. Die Physik ist eindeutig. Die Zahlen gehen auf. Und \u00fcber die gesamte Lebensdauer der Anlage sind die Einsparungen betr\u00e4chtlich.<\/p><p>Eine wassergek\u00fchlte Industriek\u00e4ltemaschine ist eine Komponente eines gr\u00f6\u00dferen <a href=\"https:\/\/www.ahkfjx.com\/de\/product-category\/industrial-chiller\/\"><strong>Industriek\u00e4ltesystem<\/strong><\/a> das K\u00fchlt\u00fcrme, Pumpen, Rohrleitungen und Steuerungen umfasst. All diese Teile m\u00fcssen zusammenarbeiten, damit das System seine potenzielle Effizienz erreicht. Aber die K\u00e4ltemaschine selbst - wenn sie richtig ausgew\u00e4hlt und gewartet wird - liefert eine Leistung, die luftgek\u00fchlt einfach nicht erreicht werden kann.<\/p><p>Wenn Sie mehr \u00fcber wassergek\u00fchlte Industriek\u00fchler wissen m\u00f6chten, lesen Sie bitte <a href=\"https:\/\/www.ahkfjx.com\/de\/what-is-a-water-cooled-industrial-chiller-how-it-works\/\"><strong>Was ist ein wassergek\u00fchlter Industriek\u00fchler? Wie sie funktioniert.<\/strong><\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-55cd06f2 e-con-full e-flex e-con e-parent\" data-id=\"55cd06f2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1821d925 elementor-widget__width-inherit elementor-widget elementor-widget-heading\" data-id=\"1821d925\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-76b8152d elementor-widget elementor-widget-n-accordion\" data-id=\"76b8152d\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Akkordeon. \u00d6ffnen Sie Links mit Enter oder Space, schlie\u00dfen Sie sie mit Escape und navigieren Sie mit den Pfeiltasten.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1990\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-1990\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Wie viel effizienter ist eine wassergek\u00fchlte K\u00e4ltemaschine als eine luftgek\u00fchlte? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1990\" class=\"elementor-element elementor-element-5a4c7436 e-con-full e-flex e-con e-child\" data-id=\"5a4c7436\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-536875e elementor-widget elementor-widget-text-editor\" data-id=\"536875e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bei Volllast in hei\u00dfem Wetter ist ein wassergek\u00fchlter Kaltwassersatz in der Regel 25-40% effizienter. Bei Teillast kann der Unterschied 40-50% oder mehr betragen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1991\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1991\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Macht der Wasserverbrauch eines K\u00fchlturms die Energieeinsparungen wieder zunichte? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1991\" class=\"elementor-element elementor-element-35d7cb24 e-con-full e-flex e-con e-child\" data-id=\"35d7cb24\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ab612eb elementor-widget elementor-widget-text-editor\" data-id=\"ab612eb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wasser hat seine Kosten, aber die sind in der Regel viel geringer als die Stromeinsparungen. In den meisten Regionen kostet das von einem K\u00fchlturm verbrauchte Wasser nur einen Bruchteil des eingesparten Stroms.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1992\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1992\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Kann ich ein bestehendes luftgek\u00fchltes System auf Wasserk\u00fchlung umr\u00fcsten? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1992\" class=\"elementor-element elementor-element-487ea8ed e-con-full e-flex e-con e-child\" data-id=\"487ea8ed\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-38e77dc elementor-widget elementor-widget-text-editor\" data-id=\"38e77dc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Praktisch nicht. Die K\u00e4ltemaschine selbst m\u00fcsste ersetzt werden. Manchmal wird jedoch ein K\u00fchlturm und eine neue wassergek\u00fchlte K\u00e4ltemaschine eingebaut, w\u00e4hrend die vorhandene luftgek\u00fchlte Einheit als Reserve beibehalten wird.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<script type=\"application\/ld+json\">{\n    \"@context\": \"https:\\\/\\\/schema.org\",\n    \"@type\": \"FAQPage\",\n    \"mainEntity\": [\n        {\n            \"@type\": \"Question\",\n            \"name\": \"How much more efficient is a water cooled chiller than an air cooled?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"At full load in hot weather, a water cooled chiller is typically 25\\u201340% more efficient. At part load, the difference can be 40\\u201350% or more.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Does the water usage of a cooling tower cancel out the energy savings?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Water has a cost, but it&#8217;s usually much lower than the electricity savings. In most regions, the water used by a cooling tower costs a fraction of the electricity saved.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Can I retrofit an existing air cooled system to water cooled?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Not practically. The chiller itself would need to be replaced. However, adding a cooling tower and new water cooled chiller while keeping the existing air cooled unit as backup is sometimes done.\"\n            }\n        }\n    ]\n}<\/script>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>There&#8217;s a reason why large facilities almost always use water cooled chillers. It&#8217;s not about complexity or first cost\u2014it&#8217;s about efficiency. A well-designed water cooled industrial chiller can use significantly less electricity than an air cooled unit doing the same job. Over years of operation, that difference adds up to real money. Having looked at [&hellip;]<\/p>","protected":false},"author":15,"featured_media":5666,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[9],"tags":[35],"class_list":["post-7259","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge","tag-industrial-chiller"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.ahkfjx.com\/de\/wp-json\/wp\/v2\/posts\/7259","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ahkfjx.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ahkfjx.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ahkfjx.com\/de\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ahkfjx.com\/de\/wp-json\/wp\/v2\/comments?post=7259"}],"version-history":[{"count":4,"href":"https:\/\/www.ahkfjx.com\/de\/wp-json\/wp\/v2\/posts\/7259\/revisions"}],"predecessor-version":[{"id":7270,"href":"https:\/\/www.ahkfjx.com\/de\/wp-json\/wp\/v2\/posts\/7259\/revisions\/7270"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ahkfjx.com\/de\/wp-json\/wp\/v2\/media\/5666"}],"wp:attachment":[{"href":"https:\/\/www.ahkfjx.com\/de\/wp-json\/wp\/v2\/media?parent=7259"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ahkfjx.com\/de\/wp-json\/wp\/v2\/categories?post=7259"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ahkfjx.com\/de\/wp-json\/wp\/v2\/tags?post=7259"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}