{"id":7273,"date":"2026-04-11T16:43:11","date_gmt":"2026-04-11T08:43:11","guid":{"rendered":"https:\/\/www.ahkfjx.com\/?p=7273"},"modified":"2026-04-10T16:52:20","modified_gmt":"2026-04-10T08:52:20","slug":"maintenance-checklist-for-industrial-water-cooled-chiller","status":"publish","type":"post","link":"https:\/\/www.ahkfjx.com\/fr\/maintenance-checklist-for-industrial-water-cooled-chiller\/","title":{"rendered":"Maintenance Checklist for Industrial Water Cooled Chiller"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"7273\" class=\"elementor elementor-7273\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1133163 e-flex e-con-boxed e-con e-parent\" data-id=\"1133163\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-477b33d elementor-widget elementor-widget-text-editor\" data-id=\"477b33d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>There&#8217;s a saying in the chiller world: a water cooled chiller doesn&#8217;t die, it gets murdered. Usually by neglect. Seen it happen more times than one would like\u2014a unit that ran fine for years, then slowly lost efficiency, started tripping on high pressure, and finally failed because nobody cleaned the tubes or treated the water.<\/p><p>The truth is, an <a href=\"https:\/\/www.ahkfjx.com\/fr\/product\/water-cooled-chiller\/\"><strong>industrial water cooled chiller<\/strong><\/a> is remarkably durable. But it needs attention. Not constant attention, but regular, predictable care. This checklist is based on watching what works in facilities that keep their chillers running for 20 or 30 years.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-581c62f elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"581c62f\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"550\" src=\"https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/5.webp\" class=\"attachment-large size-large wp-image-5666\" alt=\"REFROIDISSEUR INDUSTRIEL \u00c0 VIS REFROIDI \u00c0 L&#039;EAU\" srcset=\"https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/5.webp 800w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/5-300x206.webp 300w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/5-768x528.webp 768w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/5-18x12.webp 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4165662 elementor-widget elementor-widget-heading\" data-id=\"4165662\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Daily Checks for an Industrial Water Cooled Chiller<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ca2810 elementor-widget elementor-widget-text-editor\" data-id=\"7ca2810\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Every day, someone should walk past the chiller and look. Not a deep inspection\u2014just a few seconds of observation. Small problems are easier to fix than big ones.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be2052f elementor-widget elementor-widget-heading\" data-id=\"be2052f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">What to Look At Daily<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a3cf353 elementor-widget elementor-widget-text-editor\" data-id=\"a3cf353\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Leaving chilled water temperature: Is it at setpoint? If not, something changed.<br \/>\u2022 Operating pressures: Discharge and suction pressures. Compare to yesterday&#8217;s numbers.<br \/>\u2022 Oil level and pressure: Low oil or low oil pressure means a leak or a problem.<br \/>\u2022 Unusual noises: Rattling, hissing, or loud compressor operation.<br \/>\u2022 Water flow: Check the sight glass on the evaporator and condenser water lines.<\/p><p>A logbook helps. Writing down pressures and temperatures takes two minutes. When something drifts, the log shows it early.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1b689ae elementor-widget elementor-widget-heading\" data-id=\"1b689ae\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Cooling Tower Check<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5f0c542 elementor-widget elementor-widget-text-editor\" data-id=\"5f0c542\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The cooling tower is part of the industrial water cooled chiller system. A quick daily look at the tower basin water level and spray pattern catches problems before they affect the chiller.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8d4860f elementor-widget elementor-widget-heading\" data-id=\"8d4860f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Weekly Maintenance Tasks<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f02a8d8 elementor-widget elementor-widget-text-editor\" data-id=\"f02a8d8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Once a week, a bit more attention is worth the time.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-26ff247 elementor-widget elementor-widget-heading\" data-id=\"26ff247\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Inspections visuelles<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d927563 elementor-widget elementor-widget-text-editor\" data-id=\"d927563\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u2022 Check for leaks around the chiller, piping, and pump seals.<br \/>\u2022 Inspect the condenser water strainer pressure drop. A rising drop means debris is collecting.<br \/>\u2022 Look at the cooling tower fan belt tension and condition.<br \/>\u2022 Check the tower water distribution for even flow.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a4a33bf elementor-widget elementor-widget-heading\" data-id=\"a4a33bf\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Water Treatment Check<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fb855e2 elementor-widget elementor-widget-text-editor\" data-id=\"fb855e2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Water treatment is critical for an industrial water cooled chiller. Weekly testing should include:<br \/>\u2022 pH level (typically 7.0\u20138.5)<br \/>\u2022 Conductivity (cycles of concentration)<br \/>\u2022 Biocide and inhibitor levels<\/p><p>Poor water treatment leads to scale in the condenser tubes. Scale kills efficiency. A thin layer of scale\u2014just 1\/32 of an inch\u2014can increase energy use by 10\u201315%.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aafcf74 elementor-widget elementor-widget-heading\" data-id=\"aafcf74\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Monthly Maintenance Checklist<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3dffea1 elementor-widget elementor-widget-text-editor\" data-id=\"3dffea1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Monthly tasks go a bit deeper. These are often done by facility staff or a service contractor.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7186193 elementor-widget elementor-widget-tablepress-table\" data-id=\"7186193\" data-element_type=\"widget\" data-widget_type=\"tablepress-table.default\">\n\t\t\t\t\t\n<table id=\"tablepress-58\" class=\"tablepress tablepress-id-58\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Composant<\/th><th class=\"column-2\">Task<\/th><th class=\"column-3\">Why It Matters<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">\u00c9vaporateur<\/td><td class=\"column-2\">Check refrigerant level, inspect for oil logging<\/td><td class=\"column-3\">Low refrigerant reduces capacity; oil in evaporator hurts heat transfer<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Condenseur<\/td><td class=\"column-2\">Measure approach temperature<\/td><td class=\"column-3\">High approach indicates fouling or low water flow<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Compresseur<\/td><td class=\"column-2\">Listen for unusual sounds, check vibration<\/td><td class=\"column-3\">Early warning of bearing or valve issues<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Oil system<\/td><td class=\"column-2\">Check oil level, pressure, and temperature<\/td><td class=\"column-3\">Low oil or high discharge temp indicates problems<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Controls<\/td><td class=\"column-2\">Verify sensor readings, test safeties<\/td><td class=\"column-3\">Faulty sensors cause inefficient operation or nuisance trips<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Pumps<\/td><td class=\"column-2\">Check seal leaks, motor amperage, bearing noise<\/td><td class=\"column-3\">Pump failure stops the whole system<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Cooling tower<\/td><td class=\"column-2\">Clean basin, inspect fill, check fan operation<\/td><td class=\"column-3\">Tower problems directly affect chiller performance<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2904e15 elementor-widget elementor-widget-heading\" data-id=\"2904e15\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\"> Approach Temperature<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-69feb62 elementor-widget elementor-widget-text-editor\" data-id=\"69feb62\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>This is one of the most useful measurements. Approach temperature is the difference between refrigerant condensing temperature and leaving condenser water temperature. A clean condenser might have a 2\u20134\u00b0F approach. When approach climbs to 8\u201310\u00b0F, the condenser tubes are fouled. Time to clean them.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cffb2d5 elementor-widget elementor-widget-heading\" data-id=\"cffb2d5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Quarterly Maintenance Tasks<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1d62e95 elementor-widget elementor-widget-text-editor\" data-id=\"1d62e95\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Every three months, a more thorough inspection makes sense.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c27b512 elementor-widget elementor-widget-heading\" data-id=\"c27b512\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\"> Water Analysis<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5703e19 elementor-widget elementor-widget-text-editor\" data-id=\"5703e19\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Send a water sample from the condenser loop to a lab. They&#8217;ll check for hardness, dissolved solids, biological activity, and corrosion potential. The results guide adjustments to the chemical treatment program.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9093c40 elementor-widget elementor-widget-heading\" data-id=\"9093c40\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Electrical Inspection<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0a0ddde elementor-widget elementor-widget-text-editor\" data-id=\"0a0ddde\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u2022 Tighten all electrical connections (loose connections cause heat and failure)<br \/>\u2022 Check contactor condition (pitted or burned contacts need replacement)<br \/>\u2022 Measure voltage imbalance (should be under 2%)<br \/>\u2022 Test crankcase heaters (prevent refrigerant migration in cold weather)<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-74dce7f elementor-widget elementor-widget-heading\" data-id=\"74dce7f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Safety Device Testing<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6dd8f78 elementor-widget elementor-widget-text-editor\" data-id=\"6dd8f78\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Test the high-pressure cutout, low-pressure cutout, flow switches, and freeze protection sensors. A safety that doesn&#8217;t trip when it should is a danger to the equipment and personnel.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef1e157 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"ef1e157\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/air-cooled-industrial-chiller.jpg\" class=\"attachment-large size-large wp-image-5889\" alt=\"refroidisseur industriel \u00e0 condensation par air\" srcset=\"https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/air-cooled-industrial-chiller.jpg 800w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/air-cooled-industrial-chiller-300x300.jpg 300w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/air-cooled-industrial-chiller-150x150.jpg 150w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/air-cooled-industrial-chiller-768x768.jpg 768w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/air-cooled-industrial-chiller-12x12.jpg 12w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a36df71 elementor-widget elementor-widget-heading\" data-id=\"a36df71\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Annual Maintenance for an Industrial Water Cooled Chiller<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1fb6923 elementor-widget elementor-widget-text-editor\" data-id=\"1fb6923\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Once a year\u2014typically during a planned shutdown\u2014the chiller needs more significant attention.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-29c076a elementor-widget elementor-widget-heading\" data-id=\"29c076a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Tube Cleaning<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8edb154 elementor-widget elementor-widget-text-editor\" data-id=\"8edb154\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The evaporator and condenser tubes should be cleaned annually, more often if water quality is poor.<\/p><p>There are two methods:<br \/>\u2022 Mechanical cleaning: Using a brush or bullet pushed through each tube with water pressure.<br \/>\u2022 Chemical cleaning: Circulating a descaling solution through the tubes (requires careful neutralization).<\/p><p>Most facilities do mechanical cleaning annually. Chemical cleaning every few years if scale is present.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-99ce645 elementor-widget elementor-widget-heading\" data-id=\"99ce645\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\"> Refrigerant Analysis<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-481d517 elementor-widget elementor-widget-text-editor\" data-id=\"481d517\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Take a refrigerant sample and send it to a lab. The analysis shows:<br \/>\u2022 Acid level (high acid means moisture and potential compressor damage)<br \/>\u2022 Moisture content<br \/>\u2022 Non-condensable gases (air in the system reduces efficiency)<br \/>\u2022 Oil condition<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-def8285 elementor-widget elementor-widget-heading\" data-id=\"def8285\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Compressor Oil Change<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9b66e5f elementor-widget elementor-widget-text-editor\" data-id=\"9b66e5f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Oil degrades over time. Most manufacturers recommend changing the oil every 10,000\u201315,000 operating hours or annually. The oil analysis tells the real story.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c9ee53 elementor-widget elementor-widget-heading\" data-id=\"5c9ee53\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Cooling Tower Overhaul<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bfb30c0 elementor-widget elementor-widget-text-editor\" data-id=\"bfb30c0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The cooling tower needs annual attention:<br \/>\u2022 Clean or replace fill if fouled<br \/>\u2022 Inspect and lubricate fan bearings<br \/>\u2022 Check gearbox oil level and condition<br \/>\u2022 Inspect drift eliminators<br \/>\u2022 Clean and repair basin as needed<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-38ca445 elementor-widget elementor-widget-heading\" data-id=\"38ca445\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">The Cost of Skipping Maintenance<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-09767de elementor-widget elementor-widget-text-editor\" data-id=\"09767de\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>What happens when an industrial water cooled chiller doesn&#8217;t get this attention? The pattern is predictable.<\/p><p>Year 1-2: Slight efficiency loss. Higher energy bills. Nobody notices much.<br \/>Year 3-4: Approach temperature climbs. The chiller runs longer to meet load. More maintenance calls for nuisance trips.<br \/>Year 5-6: Compressor failure or tube leak. Major repair costing tens of thousands. The chiller is down for weeks.<br \/>Beyond: Replacement, often years before the chiller&#8217;s design life.<\/p><p>A good maintenance program costs money. But it&#8217;s a fraction of the cost of a major failure. A few thousand dollars per year in preventive maintenance avoids a $50,000\u2013$100,000 emergency repair.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a9177fa elementor-widget elementor-widget-heading\" data-id=\"a9177fa\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Record Keeping and Documentation<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ed6a8f0 elementor-widget elementor-widget-text-editor\" data-id=\"ed6a8f0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>One thing that separates well-run facilities from struggling ones is records. A binder or digital file with:<br \/>\u2022 Daily operating logs (pressures, temperatures, amperages)<br \/>\u2022 Maintenance records (what was done, when, by whom)<br \/>\u2022 Water treatment reports<br \/>\u2022 Tube cleaning dates and approach temperatures<br \/>\u2022 Repair history<\/p><p>When a chiller starts acting strangely, those records help diagnose the problem. Without them, every issue is a guess.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1f5a8d elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"c1f5a8d\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"550\" src=\"https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/4.webp\" class=\"attachment-large size-large wp-image-5667\" alt=\"REFROIDISSEUR \u00c0 AIR\" srcset=\"https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/4.webp 800w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/4-300x206.webp 300w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/4-768x528.webp 768w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/4-18x12.webp 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-af7bfcd elementor-widget elementor-widget-heading\" data-id=\"af7bfcd\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"> Working with the Larger System<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30249ce elementor-widget elementor-widget-text-editor\" data-id=\"30249ce\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>An industrial water cooled chiller is part of a larger <a href=\"https:\/\/www.ahkfjx.com\/fr\/product-category\/industrial-chiller\/\"><strong>industrial chiller system<\/strong><\/a> that includes cooling towers, pumps, piping, and controls. Maintenance on those components is just as important as maintenance on the chiller itself.<\/p><p>A chiller with clean tubes and proper refrigerant charge will still struggle if the cooling tower is fouled or the condenser water pump is worn. The system is only as strong as its weakest link.<\/p><p>That said, the chiller is usually the most expensive component. Giving it the attention it deserves\u2014daily logs, weekly checks, monthly inspections, annual overhauls\u2014pays back in reliability and energy savings.<\/p><p>If you want to know more about industrial water cooled chiller, please read <a href=\"https:\/\/www.ahkfjx.com\/fr\/what-is-a-water-cooled-industrial-chiller-how-it-works\/\"><strong>What Is a Water Cooled Industrial Chiller? How It Works.<\/strong><\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4471565a e-con-full e-flex e-con e-parent\" data-id=\"4471565a\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5b6b04e3 elementor-widget__width-inherit elementor-widget elementor-widget-heading\" data-id=\"5b6b04e3\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-45d37ddb elementor-widget elementor-widget-n-accordion\" data-id=\"45d37ddb\" data-element_type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens avec Enter ou Space, fermez-les avec Escape et naviguez avec les touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1170\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-1170\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> How often should an industrial water cooled chiller be serviced? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1170\" class=\"elementor-element elementor-element-98dc1c5 e-con-full e-flex e-con e-child\" data-id=\"98dc1c5\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f052ba1 elementor-widget elementor-widget-text-editor\" data-id=\"f052ba1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Daily visual checks, weekly water treatment tests, monthly inspections, quarterly electrical and safety checks, and annual tube cleaning and oil change. The level of service depends on runtime and water quality.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1171\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1171\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> What's the most common cause of chiller failure? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1171\" class=\"elementor-element elementor-element-16cdfd8b e-con-full e-flex e-con e-child\" data-id=\"16cdfd8b\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8b44c4d elementor-widget elementor-widget-text-editor\" data-id=\"8b44c4d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Poor water treatment leading to scale in the condenser tubes. Scale reduces heat transfer, raises condensing pressure, and eventually causes compressor failure.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1172\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1172\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\">  Can I do chiller maintenance myself or need a specialist? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1172\" class=\"elementor-element elementor-element-22c2d44b e-con-full e-flex e-con e-child\" data-id=\"22c2d44b\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cdd2f81 elementor-widget elementor-widget-text-editor\" data-id=\"cdd2f81\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Daily and weekly tasks (logs, visual checks, water treatment tests) can be done by facility staff. Annual tube cleaning, refrigerant handling, and compressor work should be done by qualified chiller technicians.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<script type=\"application\/ld+json\">{\n    \"@context\": \"https:\\\/\\\/schema.org\",\n    \"@type\": \"FAQPage\",\n    \"mainEntity\": [\n        {\n            \"@type\": \"Question\",\n            \"name\": \"How often should an industrial water cooled chiller be serviced?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Daily visual checks, weekly water treatment tests, monthly inspections, quarterly electrical and safety checks, and annual tube cleaning and oil change. The level of service depends on runtime and water quality.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What's the most common cause of chiller failure?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Poor water treatment leading to scale in the condenser tubes. Scale reduces heat transfer, raises condensing pressure, and eventually causes compressor failure.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Can I do chiller maintenance myself or need a specialist?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Daily and weekly tasks (logs, visual checks, water treatment tests) can be done by facility staff. Annual tube cleaning, refrigerant handling, and compressor work should be done by qualified chiller technicians.\"\n            }\n        }\n    ]\n}<\/script>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>There&#8217;s a saying in the chiller world: a water cooled chiller doesn&#8217;t die, it gets murdered. Usually by neglect. Seen it happen more times than one would like\u2014a unit that ran fine for years, then slowly lost efficiency, started tripping on high pressure, and finally failed because nobody cleaned the tubes or treated the water. [&hellip;]<\/p>","protected":false},"author":15,"featured_media":5932,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[9],"tags":[],"class_list":["post-7273","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/posts\/7273","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/comments?post=7273"}],"version-history":[{"count":7,"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/posts\/7273\/revisions"}],"predecessor-version":[{"id":7286,"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/posts\/7273\/revisions\/7286"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/media\/5932"}],"wp:attachment":[{"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/media?parent=7273"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/categories?post=7273"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/tags?post=7273"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}