{"id":7273,"date":"2026-04-11T16:43:11","date_gmt":"2026-04-11T08:43:11","guid":{"rendered":"https:\/\/www.ahkfjx.com\/?p=7273"},"modified":"2026-04-15T17:26:39","modified_gmt":"2026-04-15T09:26:39","slug":"maintenance-checklist-for-industrial-water-cooled-chiller","status":"publish","type":"post","link":"https:\/\/www.ahkfjx.com\/fr\/maintenance-checklist-for-industrial-water-cooled-chiller\/","title":{"rendered":"Liste de contr\u00f4le de l'entretien des refroidisseurs industriels \u00e0 eau"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"7273\" class=\"elementor elementor-7273\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1133163 e-flex e-con-boxed e-con e-parent\" data-id=\"1133163\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-477b33d elementor-widget elementor-widget-text-editor\" data-id=\"477b33d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Dans le monde des refroidisseurs, on dit qu'un refroidisseur \u00e0 eau ne meurt pas, mais qu'il est assassin\u00e9. G\u00e9n\u00e9ralement par n\u00e9gligence. J'ai vu cela se produire plus souvent qu'on ne le souhaiterait - une unit\u00e9 qui a bien fonctionn\u00e9 pendant des ann\u00e9es, puis qui a lentement perdu de son efficacit\u00e9, qui a commenc\u00e9 \u00e0 se d\u00e9clencher sur haute pression, et qui est finalement tomb\u00e9e en panne parce que personne n'a nettoy\u00e9 les tubes ou trait\u00e9 l'eau.<\/p><p>La v\u00e9rit\u00e9 est qu'un <a href=\"https:\/\/www.ahkfjx.com\/fr\/product\/water-cooled-chiller\/\"><strong>refroidisseur industriel \u00e0 eau<\/strong><\/a> est remarquablement durable. Mais il a besoin d'attention. Pas une attention constante, mais un entretien r\u00e9gulier et pr\u00e9visible. Cette liste de contr\u00f4le est bas\u00e9e sur l'observation de ce qui fonctionne dans les installations qui maintiennent leurs refroidisseurs en \u00e9tat de marche pendant 20 ou 30 ans.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-581c62f elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"581c62f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"550\" src=\"https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/5.webp\" class=\"attachment-large size-large wp-image-5666\" alt=\"REFROIDISSEUR INDUSTRIEL \u00c0 VIS REFROIDI \u00c0 L&#039;EAU\" srcset=\"https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/5.webp 800w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/5-300x206.webp 300w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/5-768x528.webp 768w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/5-18x12.webp 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4165662 elementor-widget elementor-widget-heading\" data-id=\"4165662\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Contr\u00f4les quotidiens d'un refroidisseur industriel \u00e0 eau<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ca2810 elementor-widget elementor-widget-text-editor\" data-id=\"7ca2810\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Chaque jour, quelqu'un doit passer devant le refroidisseur et le regarder. Il ne s'agit pas d'une inspection approfondie, mais de quelques secondes d'observation. Les petits probl\u00e8mes sont plus faciles \u00e0 r\u00e9soudre que les gros.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be2052f elementor-widget elementor-widget-heading\" data-id=\"be2052f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Ce qu'il faut regarder au quotidien<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a3cf353 elementor-widget elementor-widget-text-editor\" data-id=\"a3cf353\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Temp\u00e9rature de sortie de l'eau r\u00e9frig\u00e9r\u00e9e : Est-elle au point de consigne ? Si ce n'est pas le cas, quelque chose a chang\u00e9.<br \/>- Pressions de fonctionnement : Pressions de refoulement et d'aspiration. Comparer avec les chiffres d'hier.<br \/>- Niveau et pression d'huile : Un niveau d'huile bas ou une pression d'huile basse signifie qu'il y a une fuite ou un probl\u00e8me.<br \/>- Bruits inhabituels : cliquetis, sifflement ou fonctionnement bruyant du compresseur.<br \/>- D\u00e9bit d'eau : V\u00e9rifier le voyant sur les conduites d'eau de l'\u00e9vaporateur et du condenseur.<\/p><p>Un carnet de bord est utile. Noter les pressions et les temp\u00e9ratures prend deux minutes. Lorsque quelque chose d\u00e9rive, le carnet de bord le signale rapidement.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1b689ae elementor-widget elementor-widget-heading\" data-id=\"1b689ae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Contr\u00f4le de la tour de refroidissement<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5f0c542 elementor-widget elementor-widget-text-editor\" data-id=\"5f0c542\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La tour de refroidissement fait partie du syst\u00e8me industriel de refroidissement par eau. Un rapide examen quotidien du niveau d'eau du bassin de la tour et du mod\u00e8le de pulv\u00e9risation permet de d\u00e9tecter les probl\u00e8mes avant qu'ils n'affectent le refroidisseur.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8d4860f elementor-widget elementor-widget-heading\" data-id=\"8d4860f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">T\u00e2ches de maintenance hebdomadaires<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f02a8d8 elementor-widget elementor-widget-text-editor\" data-id=\"f02a8d8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Une fois par semaine, un peu plus d'attention vaut la peine.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-26ff247 elementor-widget elementor-widget-heading\" data-id=\"26ff247\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Inspections visuelles<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d927563 elementor-widget elementor-widget-text-editor\" data-id=\"d927563\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>- V\u00e9rifier l'absence de fuites autour du refroidisseur, de la tuyauterie et des joints de la pompe.<br \/>- Inspectez la chute de pression de la cr\u00e9pine d'eau du condenseur. Une chute de pression croissante signifie que des d\u00e9bris s'accumulent.<br \/>- V\u00e9rifier la tension et l'\u00e9tat de la courroie du ventilateur de la tour de refroidissement.<br \/>- V\u00e9rifier que la distribution de l'eau de la tour est r\u00e9guli\u00e8re.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a4a33bf elementor-widget elementor-widget-heading\" data-id=\"a4a33bf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Contr\u00f4le du traitement de l'eau<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fb855e2 elementor-widget elementor-widget-text-editor\" data-id=\"fb855e2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le traitement de l'eau est essentiel pour un refroidisseur industriel refroidi \u00e0 l'eau. Les tests hebdomadaires doivent porter sur les \u00e9l\u00e9ments suivants<br \/>- le niveau de pH (g\u00e9n\u00e9ralement de 7,0 \u00e0 8,5)<br \/>- Conductivit\u00e9 (cycles de concentration)<br \/>- Niveaux de biocides et d'inhibiteurs<\/p><p>Un mauvais traitement de l'eau entra\u00eene l'entartrage des tubes du condenseur. Le tartre nuit \u00e0 l'efficacit\u00e9. Une fine couche de tartre - seulement 1\/32 de pouce - peut augmenter la consommation d'\u00e9nergie de 10-15%.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aafcf74 elementor-widget elementor-widget-heading\" data-id=\"aafcf74\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Liste de contr\u00f4le de l'entretien mensuel<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3dffea1 elementor-widget elementor-widget-text-editor\" data-id=\"3dffea1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Les t\u00e2ches mensuelles sont un peu plus approfondies. Elles sont souvent effectu\u00e9es par le personnel de l'\u00e9tablissement ou par un prestataire de services.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7186193 elementor-widget elementor-widget-tablepress-table\" data-id=\"7186193\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"tablepress-table.default\">\n\t\t\t\t\t\n<table id=\"tablepress-58\" class=\"tablepress tablepress-id-58\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Composant<\/th><th class=\"column-2\">T\u00e2che<\/th><th class=\"column-3\">Pourquoi c'est important<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">\u00c9vaporateur<\/td><td class=\"column-2\">Contr\u00f4ler le niveau de r\u00e9frig\u00e9rant, v\u00e9rifier l'absence d'accumulation d'huile<\/td><td class=\"column-3\">Le manque de r\u00e9frig\u00e9rant r\u00e9duit la capacit\u00e9 ; l'huile dans l'\u00e9vaporateur nuit au transfert de chaleur.<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Condenseur<\/td><td class=\"column-2\">Mesure de la temp\u00e9rature d'approche<\/td><td class=\"column-3\">Une approche \u00e9lev\u00e9e indique un encrassement ou un faible d\u00e9bit d'eau<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Compresseur<\/td><td class=\"column-2\">\u00c9couter les bruits inhabituels, v\u00e9rifier les vibrations<\/td><td class=\"column-3\">Alerte pr\u00e9coce en cas de probl\u00e8mes de roulements ou de soupapes<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Syst\u00e8me d'huile<\/td><td class=\"column-2\">V\u00e9rifier le niveau, la pression et la temp\u00e9rature de l'huile<\/td><td class=\"column-3\">Un niveau d'huile bas ou une temp\u00e9rature de refoulement \u00e9lev\u00e9e indiquent des probl\u00e8mes<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Contr\u00f4les<\/td><td class=\"column-2\">V\u00e9rifier la lecture des capteurs, tester les s\u00e9curit\u00e9s<\/td><td class=\"column-3\">Des capteurs d\u00e9fectueux entra\u00eenent un fonctionnement inefficace ou des d\u00e9clenchements intempestifs.<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Pompes<\/td><td class=\"column-2\">V\u00e9rifier les fuites des joints, l'amp\u00e9rage du moteur, le bruit des roulements.<\/td><td class=\"column-3\">La d\u00e9faillance de la pompe arr\u00eate l'ensemble du syst\u00e8me<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Tour de refroidissement<\/td><td class=\"column-2\">Nettoyer le bassin, inspecter le remplissage, v\u00e9rifier le fonctionnement du ventilateur<\/td><td class=\"column-3\">Les probl\u00e8mes de tour affectent directement les performances du refroidisseur<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-58 from cache -->\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2904e15 elementor-widget elementor-widget-heading\" data-id=\"2904e15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\"> Temp\u00e9rature d'approche<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-69feb62 elementor-widget elementor-widget-text-editor\" data-id=\"69feb62\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>C'est l'une des mesures les plus utiles. La temp\u00e9rature d'approche est la diff\u00e9rence entre la temp\u00e9rature de condensation du r\u00e9frig\u00e9rant et la temp\u00e9rature de l'eau de sortie du condenseur. Un condenseur propre peut avoir une temp\u00e9rature d'approche de 2-4\u00b0F. Lorsque la temp\u00e9rature d'approche atteint 8-10\u00b0F, les tubes du condenseur sont encrass\u00e9s. Il est temps de les nettoyer.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cffb2d5 elementor-widget elementor-widget-heading\" data-id=\"cffb2d5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">T\u00e2ches de maintenance trimestrielles<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1d62e95 elementor-widget elementor-widget-text-editor\" data-id=\"1d62e95\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Tous les trois mois, une inspection plus approfondie s'impose.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c27b512 elementor-widget elementor-widget-heading\" data-id=\"c27b512\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\"> Analyse de l'eau<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5703e19 elementor-widget elementor-widget-text-editor\" data-id=\"5703e19\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Envoyez un \u00e9chantillon d'eau de la boucle du condenseur \u00e0 un laboratoire. Il v\u00e9rifiera la duret\u00e9, les solides dissous, l'activit\u00e9 biologique et le potentiel de corrosion. Les r\u00e9sultats permettent d'ajuster le programme de traitement chimique.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9093c40 elementor-widget elementor-widget-heading\" data-id=\"9093c40\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Inspection \u00e9lectrique<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0a0ddde elementor-widget elementor-widget-text-editor\" data-id=\"0a0ddde\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>- Serrer toutes les connexions \u00e9lectriques (les connexions l\u00e2ches provoquent de la chaleur et des pannes).<br \/>- V\u00e9rifier l'\u00e9tat du contacteur (les contacts piqu\u00e9s ou br\u00fbl\u00e9s doivent \u00eatre remplac\u00e9s).<br \/>- Mesurer le d\u00e9s\u00e9quilibre de tension (devrait \u00eatre inf\u00e9rieur \u00e0 2%)<br \/>- Tester les r\u00e9chauffeurs de carter (emp\u00eachent la migration du r\u00e9frig\u00e9rant par temps froid)<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-74dce7f elementor-widget elementor-widget-heading\" data-id=\"74dce7f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Essai des dispositifs de s\u00e9curit\u00e9<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6dd8f78 elementor-widget elementor-widget-text-editor\" data-id=\"6dd8f78\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Testez la coupure haute pression, la coupure basse pression, les interrupteurs de d\u00e9bit et les capteurs de protection contre le gel. Un dispositif de s\u00e9curit\u00e9 qui ne se d\u00e9clenche pas lorsqu'il le devrait constitue un danger pour l'\u00e9quipement et le personnel.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef1e157 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"ef1e157\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/air-cooled-industrial-chiller.jpg\" class=\"attachment-large size-large wp-image-5889\" alt=\"refroidisseur industriel \u00e0 condensation par air\" srcset=\"https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/air-cooled-industrial-chiller.jpg 800w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/air-cooled-industrial-chiller-300x300.jpg 300w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/air-cooled-industrial-chiller-150x150.jpg 150w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/air-cooled-industrial-chiller-768x768.jpg 768w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/air-cooled-industrial-chiller-12x12.jpg 12w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a36df71 elementor-widget elementor-widget-heading\" data-id=\"a36df71\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Entretien annuel d'un refroidisseur industriel \u00e0 eau<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1fb6923 elementor-widget elementor-widget-text-editor\" data-id=\"1fb6923\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Une fois par an, g\u00e9n\u00e9ralement lors d'un arr\u00eat planifi\u00e9, le refroidisseur doit faire l'objet d'une attention plus soutenue.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-29c076a elementor-widget elementor-widget-heading\" data-id=\"29c076a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Nettoyage des tubes<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8edb154 elementor-widget elementor-widget-text-editor\" data-id=\"8edb154\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Les tubes de l'\u00e9vaporateur et du condenseur doivent \u00eatre nettoy\u00e9s chaque ann\u00e9e, plus souvent si la qualit\u00e9 de l'eau est mauvaise.<\/p><p>Il existe deux m\u00e9thodes :<br \/>- Nettoyage m\u00e9canique : Utilisation d'une brosse ou d'une balle pass\u00e9e dans chaque tube sous la pression de l'eau.<br \/>- Nettoyage chimique : Faire circuler une solution de d\u00e9tartrage dans les tubes (n\u00e9cessite une neutralisation minutieuse).<\/p><p>La plupart des installations proc\u00e8dent \u00e0 un nettoyage m\u00e9canique annuel. Le nettoyage chimique a lieu tous les deux ans en cas d'entartrage.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-99ce645 elementor-widget elementor-widget-heading\" data-id=\"99ce645\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\"> Analyse des fluides frigorig\u00e8nes<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-481d517 elementor-widget elementor-widget-text-editor\" data-id=\"481d517\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pr\u00e9levez un \u00e9chantillon de r\u00e9frig\u00e9rant et envoyez-le \u00e0 un laboratoire. L'analyse montre :<br \/>- Niveau d'acide (un niveau d'acide \u00e9lev\u00e9 est synonyme d'humidit\u00e9 et d'endommagement potentiel du compresseur)<br \/>- Teneur en eau<br \/>- Gaz non condensables (l'air dans le syst\u00e8me r\u00e9duit l'efficacit\u00e9)<br \/>- \u00c9tat de l'huile<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-def8285 elementor-widget elementor-widget-heading\" data-id=\"def8285\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Remplacement de l'huile du compresseur<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9b66e5f elementor-widget elementor-widget-text-editor\" data-id=\"9b66e5f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>L'huile se d\u00e9grade avec le temps. La plupart des fabricants recommandent de changer l'huile toutes les 10 000 \u00e0 15 000 heures de fonctionnement ou tous les ans. L'analyse de l'huile en dit long.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c9ee53 elementor-widget elementor-widget-heading\" data-id=\"5c9ee53\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">R\u00e9vision des tours de refroidissement<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bfb30c0 elementor-widget elementor-widget-text-editor\" data-id=\"bfb30c0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La tour de refroidissement doit faire l'objet d'une attention annuelle :<br \/>- Nettoyer ou remplacer le remplissage s'il est encrass\u00e9<br \/>- Inspecter et lubrifier les roulements du ventilateur<br \/>- V\u00e9rifier le niveau et l'\u00e9tat de l'huile de bo\u00eete de vitesses<br \/>- Inspecter les \u00e9liminateurs de d\u00e9rive<br \/>- Nettoyer et r\u00e9parer le bassin si n\u00e9cessaire<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-38ca445 elementor-widget elementor-widget-heading\" data-id=\"38ca445\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Le co\u00fbt de l'absence de maintenance<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-09767de elementor-widget elementor-widget-text-editor\" data-id=\"09767de\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Que se passe-t-il lorsqu'un refroidisseur industriel \u00e0 eau ne re\u00e7oit pas cette attention ? Le sch\u00e9ma est pr\u00e9visible.<\/p><p>Ann\u00e9e 1-2 : L\u00e9g\u00e8re perte d'efficacit\u00e9. Factures d'\u00e9nergie plus \u00e9lev\u00e9es. Personne ne le remarque vraiment.<br \/>Ann\u00e9e 3-4 : La temp\u00e9rature d'approche augmente. Le refroidisseur fonctionne plus longtemps pour r\u00e9pondre \u00e0 la charge. Plus d'appels de maintenance pour des d\u00e9clenchements intempestifs.<br \/>Ann\u00e9e 5-6 : D\u00e9faillance du compresseur ou fuite du tube. R\u00e9paration majeure co\u00fbtant des dizaines de milliers d'euros. Le refroidisseur est en panne pendant des semaines.<br \/>Au-del\u00e0 : Remplacement, souvent des ann\u00e9es avant la dur\u00e9e de vie pr\u00e9vue du refroidisseur.<\/p><p>Un bon programme de maintenance co\u00fbte de l'argent. Mais cela ne repr\u00e9sente qu'une fraction du co\u00fbt d'une panne majeure. Quelques milliers de dollars par an en maintenance pr\u00e9ventive permettent d'\u00e9viter une r\u00e9paration d'urgence de $50 000-$100 000.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a9177fa elementor-widget elementor-widget-heading\" data-id=\"a9177fa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Tenue de registres et documentation<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ed6a8f0 elementor-widget elementor-widget-text-editor\" data-id=\"ed6a8f0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Les dossiers sont l'un des \u00e9l\u00e9ments qui distinguent les \u00e9tablissements bien g\u00e9r\u00e9s des \u00e9tablissements en difficult\u00e9. Un classeur ou un fichier num\u00e9rique contenant :<br \/>- Journaux d'exploitation quotidiens (pressions, temp\u00e9ratures, amp\u00e9rages)<br \/>- Registres de maintenance (ce qui a \u00e9t\u00e9 fait, quand, par qui)<br \/>- Rapports sur le traitement des eaux<br \/>- Dates de nettoyage des tubes et temp\u00e9ratures d'approche<br \/>- Historique des r\u00e9parations<\/p><p>Lorsqu'un refroidisseur commence \u00e0 se comporter de mani\u00e8re \u00e9trange, ces enregistrements permettent de diagnostiquer le probl\u00e8me. Sans eux, chaque probl\u00e8me n'est qu'une supposition.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1f5a8d elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"c1f5a8d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"550\" src=\"https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/4.webp\" class=\"attachment-large size-large wp-image-5667\" alt=\"REFROIDISSEUR \u00c0 AIR\" srcset=\"https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/4.webp 800w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/4-300x206.webp 300w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/4-768x528.webp 768w, https:\/\/www.ahkfjx.com\/wp-content\/uploads\/2025\/08\/4-18x12.webp 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-af7bfcd elementor-widget elementor-widget-heading\" data-id=\"af7bfcd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"> Travailler avec le grand syst\u00e8me<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30249ce elementor-widget elementor-widget-text-editor\" data-id=\"30249ce\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un refroidisseur industriel \u00e0 eau fait partie d'un ensemble plus vaste. <a href=\"https:\/\/www.ahkfjx.com\/fr\/product-category\/industrial-chiller\/\"><strong>syst\u00e8me de refroidissement industriel<\/strong><\/a> qui comprend les tours de refroidissement, les pompes, la tuyauterie et les commandes. L'entretien de ces composants est tout aussi important que celui du refroidisseur lui-m\u00eame.<\/p><p>Un refroidisseur dont les tubes sont propres et la charge de fluide frigorig\u00e8ne correcte aura toujours des difficult\u00e9s si la tour de refroidissement est encrass\u00e9e ou si la pompe \u00e0 eau du condenseur est us\u00e9e. La solidit\u00e9 du syst\u00e8me d\u00e9pend de son maillon le plus faible.<\/p><p>Cela dit, le refroidisseur est g\u00e9n\u00e9ralement le composant le plus co\u00fbteux. En lui accordant l'attention qu'il m\u00e9rite - registres quotidiens, contr\u00f4les hebdomadaires, inspections mensuelles, r\u00e9visions annuelles - on obtient des r\u00e9sultats en termes de fiabilit\u00e9 et d'\u00e9conomies d'\u00e9nergie.<\/p><p>Si vous souhaitez en savoir plus sur les refroidisseurs industriels \u00e0 eau, veuillez lire le document suivant <a href=\"https:\/\/www.ahkfjx.com\/fr\/what-is-a-water-cooled-industrial-chiller-how-it-works\/\"><strong>Qu'est-ce qu'un refroidisseur industriel \u00e0 eau ? Comment cela fonctionne-t-il ?.<\/strong><\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4471565a e-con-full e-flex e-con e-parent\" data-id=\"4471565a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5b6b04e3 elementor-widget__width-inherit elementor-widget elementor-widget-heading\" data-id=\"5b6b04e3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-45d37ddb elementor-widget elementor-widget-n-accordion\" data-id=\"45d37ddb\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens avec Enter ou Space, fermez-les avec Escape et naviguez avec les touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1170\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-1170\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelle est la fr\u00e9quence d'entretien d'un refroidisseur industriel \u00e0 eau ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1170\" class=\"elementor-element elementor-element-98dc1c5 e-con-full e-flex e-con e-child\" data-id=\"98dc1c5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f052ba1 elementor-widget elementor-widget-text-editor\" data-id=\"f052ba1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Contr\u00f4les visuels quotidiens, tests hebdomadaires de traitement de l'eau, inspections mensuelles, contr\u00f4les \u00e9lectriques et de s\u00e9curit\u00e9 trimestriels, nettoyage annuel des tubes et vidange d'huile. Le niveau de service d\u00e9pend de la dur\u00e9e de fonctionnement et de la qualit\u00e9 de l'eau.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1171\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1171\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelle est la cause la plus fr\u00e9quente de d\u00e9faillance d'un refroidisseur ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1171\" class=\"elementor-element elementor-element-16cdfd8b e-con-full e-flex e-con e-child\" data-id=\"16cdfd8b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8b44c4d elementor-widget elementor-widget-text-editor\" data-id=\"8b44c4d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un mauvais traitement de l'eau entra\u00eene la formation de tartre dans les tubes du condenseur. Le tartre r\u00e9duit le transfert de chaleur, augmente la pression de condensation et finit par provoquer une panne du compresseur.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1172\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1172\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\">  Puis-je effectuer moi-m\u00eame l'entretien du refroidisseur ou dois-je faire appel \u00e0 un sp\u00e9cialiste ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1172\" class=\"elementor-element elementor-element-22c2d44b e-con-full e-flex e-con e-child\" data-id=\"22c2d44b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cdd2f81 elementor-widget elementor-widget-text-editor\" data-id=\"cdd2f81\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Les t\u00e2ches quotidiennes et hebdomadaires (registres, contr\u00f4les visuels, tests de traitement de l'eau) peuvent \u00eatre effectu\u00e9es par le personnel de l'\u00e9tablissement. Le nettoyage annuel des tubes, la manipulation du r\u00e9frig\u00e9rant et les travaux sur les compresseurs doivent \u00eatre effectu\u00e9s par des techniciens qualifi\u00e9s.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<script type=\"application\/ld+json\">{\n    \"@context\": \"https:\\\/\\\/schema.org\",\n    \"@type\": \"FAQPage\",\n    \"mainEntity\": [\n        {\n            \"@type\": \"Question\",\n            \"name\": \"How often should an industrial water cooled chiller be serviced?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Daily visual checks, weekly water treatment tests, monthly inspections, quarterly electrical and safety checks, and annual tube cleaning and oil change. The level of service depends on runtime and water quality.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What's the most common cause of chiller failure?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Poor water treatment leading to scale in the condenser tubes. Scale reduces heat transfer, raises condensing pressure, and eventually causes compressor failure.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Can I do chiller maintenance myself or need a specialist?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Daily and weekly tasks (logs, visual checks, water treatment tests) can be done by facility staff. Annual tube cleaning, refrigerant handling, and compressor work should be done by qualified chiller technicians.\"\n            }\n        }\n    ]\n}<\/script>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Dans le monde des refroidisseurs, on dit qu'un refroidisseur \u00e0 eau ne meurt pas, mais qu'il est assassin\u00e9. G\u00e9n\u00e9ralement par n\u00e9gligence. J'ai vu cela se produire plus souvent qu'on ne le souhaiterait - une unit\u00e9 qui a bien fonctionn\u00e9 pendant des ann\u00e9es, puis qui a lentement perdu de son efficacit\u00e9, qui a commenc\u00e9 \u00e0 se d\u00e9clencher sur haute pression, et qui est finalement tomb\u00e9e en panne parce que personne n'a nettoy\u00e9 les tubes ou trait\u00e9 l'eau. [...]<\/p>","protected":false},"author":15,"featured_media":5932,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[9],"tags":[35],"class_list":["post-7273","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge","tag-industrial-chiller"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/posts\/7273","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/comments?post=7273"}],"version-history":[{"count":7,"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/posts\/7273\/revisions"}],"predecessor-version":[{"id":7286,"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/posts\/7273\/revisions\/7286"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/media\/5932"}],"wp:attachment":[{"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/media?parent=7273"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/categories?post=7273"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ahkfjx.com\/fr\/wp-json\/wp\/v2\/tags?post=7273"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}